M-SOLV Dual-Laser Microfabrication System

IR + DUV in one platform for micron-scale fabrication · Process optimisation · Vision-guided alignment

Design → Toolpaths → Laser Fabrication → Lamination → Assembly → Metrology → Test → Iterate

What this enables

  • Micron-scale features with clean edges and controlled taper

  • Fast iteration via parameter sweeps and recipe tiling (optimize in hours, not weeks)

  • Tight alignment across multi-step builds (registration + calibrated scanners)

  • Production-ready repeatability with documented process parameters & logs

Hardware highlights

  • Lasers: IR 1064 nm (up to 20 W, 3–500 ns, to 1 MHz), DUV 266 nm (up to 4 W, ns-class pulses, to 100 kHz)

  • Motion platform: 500 × 300 mm XY travel; accuracy ±5 µm; repeatability ±0.5 µm; 100 nm resolution. Z travel 100 mm; repeatability ±1 µm; 0.5 µm resolution

  • Optics: adjustable beam expanders, CNC aperture (top-hat/DOE), dual galvo scanners with f-theta lenses; DUV line includes high-NA focusing path for near-vertical sidewalls

  • Vision & metrology: off-axis high-mag camera (auto/assisted alignment to fiducials); non-contact height sensor for auto-focus & levelling

  • Safety enclosure: Class 1 during normal operation (interlocked), with maintenance/override modes for service by qualified personnel

optics-light-scaled optimized
Optics Table
IMG_0161-1024x768
Vacuum Chuck & Fume Extraction

Software & workflow

Process Optimisation (parameter grid)

  • Program a 2D grid of patterns with X/Y variable parameters (e.g., power, PRF, speed, hatch/overlap), auto-mark, then inspect → select best window. Save/load configs to reuse.

Recipe Editor & Tiling

  • Build multi-tier recipes (plate → array → device → layers), assign DXFs and mark parameters, tile large DXFs into scan-field-sized “chunks,” and position precisely for big areas.

Scanner Calibration

  • Mark calibration grids, auto-measure, generate & apply correction files for field linearity and scale; verify with re-runs for traceable accuracy.

Camera↔Beam Calibration

  • Re-establish camera/beam offset after optics/camera changes to keep fiducial alignment tight.

Height Mapping

  • Create a height map CSV from the optical sensor to maintain focus over warped/stacked builds.

Inspection Utility

  • Full-window vision inspection, basic measurement & position save; export imagery for reports/QA.

Dual-Laser System Process Optimization Application
User Interface - Process Optimization

Spec highlights

Lasers (2 independent) IR: 1064 nm, up to 20 W, 3–500 ns, ≤1 MHz PRF DUV channel 266 nm, up to 4 W, ≤33 ns, ≤100 kHz PRF
Beam delivery Adjustable beam expanders, CNC aperture, galvo scanners, f-theta lenses Advanced optics DOE insertable; DUV CNC switch mirror → high-NA focusing lens
XY travel / speed 500 mm × 300 mm, up to 200 mm/s XY accuracy / repeatability ±5 µm accuracy, ±0.5 µm repeatability; 100 nm resolution
Z travel 100 mm Z accuracy / repeatability ±8 µm accuracy, ±1 µm repeatability; 0.5 µm resolution
Workholding 6″×6″ levellable porous vacuum chuck Metrology aids Off-axis high-mag camera; non-contact optical height sensor
Machine structure Granite slab + granite bridge on vibration isolators Safety / modes Safety PLC, interlocks; Production & Maintenance modes
Footprint / mass ≈1700 (L) × 1100 (W) × 1800 (H) mm; ~1700 kg Noise (processing) ~72 dB at operator position
Utilities (power) 380/415 VAC 3-phase + E; 50/60 Hz; peak 32 A; IEC 309 5-pin 32 A Utilities (air) 0.6 MPa, ~20 SLPM (max), oil-free dry air; 8/12 mm push-fit
Debris handling External extract unit (HEPA/chem filter), vacuum pump Laser thermal mgmt AO (DUV) controller & chiller in 19″ rack
Process Optimisation Grid-based parameter sweeps (X/Y variables), save/load configs Recipe Editor Tiered plate→device→layer tree; DXF-driven layers; preview
Scanner Calibration Mark-capture grid, tolerance & interpolation; correction file apply Camera↔Beam Offset Guided mark/centre/save workflow to maintain alignment
Height Mapping Camera-based grid collection → CSV height map; thickness assist Inspection Utility Large live view, motion control, pattern training, save positions
DXF Creator On-tool simple DXF drawing & export Vision & Alignment Fiducials, alignment routines per node; stitched execution

Parameter DOE: Polyimide Micro-Aperture Cutting

Objective: identify a process window that yields crisp edges, minimal HAZ, and ±(target) µm dimensional accuracy. DOE varied power, PRF, scan speed, and overlap on a fixed toolpath.

Insert BEFORE image (edge/HAZ)
Insert AFTER image (optimized)
Pattern ID Power (%) PRF (kHz) Speed (mm/s) Overlap (%) Passes Result notes
A1 Edge, taper, HAZ, dim. error
A2
B1
B2
C1
C2
Selected Window / Recipe (example placeholder)
  • Power: [xx] % · PRF: [xx] kHz · Speed: [x.xx] mm/s · Overlap: [xx] % · Passes: [x]
  • Edge quality: [text]; HAZ: [text]; Dimensional error: ±[x] µm
  • Rationale: [why this window—balance of edge/throughput/dimensions]

Have a tricky material or geometry?

Let’s run a parameter DOE and show you the data.